The stove is set where it will burn all winter, the pellet bags are stacked nearby, and now the vent has to get from the back of the stove to the outside. Stove pipe for pellet stove installation means Type L double-wall vent pipe sized to the stove’s flue outlet, run through the wall or up through the roof. The pipe carries hot flue gas outside, and the diameter, length and clearance decide whether the run fits. This guide explains what the parts are, how to match them to the stove, and what to check before a certified pro does the install.
FirewoodGearHQ earns a small commission if you buy through links on this page. The price you pay stays the same. Read our affiliate disclosure.
The quick answer
Pellet stove vent pipe is Type L double-wall pipe, sold in 3-inch and 4-inch diameters, with 1-inch clearance to combustibles and a UL 641 listing on the DuraVent and Stove Parts 4 Less listings. A 4-inch DuraVent pipe comes in a 24-inch length with a 22.5-inch installed length, and a 3-inch DuraVent pipe comes in a 36-inch length. Match the pipe diameter to the stove’s flue outlet, keep the 1-inch clearance the listings state, and have a certified pro install it per the maker instructions and local code.
What pellet stove pipe is
Pellet stove pipe is not the same as wood stove pipe. The DuraVent and Stove Parts 4 Less listings describe Type L vent pipe as double-wall pipe with a stainless steel inner wall and a galvalume steel outer wall. DuraVent describes a 444/304 stainless steel welded inner wall with a laser-welded galvalume steel outer wall, and a twist-lock connection that joins lengths without mechanical fasteners. The DuraVent pipe is built for continuous flue temperatures up to 570°F, and the Selkirk kits state that flue gases must not exceed 570°F. See stove pipe vs chimney pipe for how vent pipe differs from chimney pipe.
Stove pipe for pellet stove installation: match the diameter first
Diameter comes first, because every other part follows it. The listings show 3-inch and 4-inch Type L pipe: DuraVent sells a 3-inch pipe in a 36-inch length and a 4-inch pipe in a 24-inch length, and Selkirk sells thru-the-wall kits in 3-inch and 3-4-inch sizes. The Yaocom adapter (on Amazon) measures 3” x 6” with a 6″ diameter, and it is made to join a pellet stove flue to a chimney pipe. Check the stove’s flue outlet and match the pipe to it: a 3-inch outlet takes 3-inch pipe, and a 4-inch outlet takes 4-inch pipe. For the full range of sizes, see stove pipe sizes and the chimney liner size chart.
Lengths and the parts in a kit
Pipe comes in fixed lengths, and the installed length runs shorter than the pipe length: the DuraVent 4-inch pipe is a 24-inch length with a 22.5-inch installed length, and the DuraVent 3-inch pipe is a 36-inch length. DuraVent also sells a vent pipe kit in an 84-inch size. A thru-the-wall kit bundles the parts for a horizontal run: the Selkirk 3-inch kit and the 3-4-inch kit are both designed for horizontal installations only. The Coldairsoap fresh air intake kit (on Amazon) is a different kind of kit: it brings outside air in for combustion, with a flex pipe that stretches to 59 inches, 3 stainless steel wall plates, 1 telescopic aluminum flex pipe, 2 screw clamps and 3 hole saws.
| Part | What the listing states |
|---|---|
| DuraVent PelletVent Pro 4-inch pipe | 24-inch length, 22.5-inch installed length, 570°F, 1-inch clearance |
| DuraVent PelletVent Pro 3-inch pipe | 36-inch length, 1-inch clearance, limited lifetime warranty |
| DuraVent vent pipe kit | 84-inch kit |
| Selkirk Type L pellet kit, 3-inch | Thru-the-wall, horizontal only, flue gas up to 570°F |
| Selkirk Type L pellet kit, 3-4-inch | Thru-the-wall, horizontal only, flue gas up to 570°F |
| Yaocom chimney adapter | 3” x 6”, 6″ diameter, galvanized steel, gasketed joint |
| Coldairsoap fresh air intake kit | Flex pipe to 59 inches, 45-degree weatherboard, up to 752°F |
Count the parts before the pro arrives: pipe lengths, the adapter, and the kit contents. The pellet stove installation kit guide lists the parts for a full install.
Clearance and listings to check
Clearance is the gap between the pipe and anything that can burn, and the listings state it plainly. The DuraVent 4-inch pipe and the Stove Parts 4 Less kit both state 1-inch clearance to combustibles, in the USA and Canada. The DuraVent 3-inch pipe states the same 1-inch clearance. Look for the listing mark as well: the DuraVent 4-inch pipe is c-UL-us listed to UL 641, and the Stove Parts 4 Less kit is c-UL-us listed to UL 641 and ULC listed to ULC S609 and ULC/ORD C441. A pipe without a stated listing leaves the clearance question open, so check the listing before the pipe goes in. Install per the maker instructions and local code, fit smoke and CO alarms, and plan an annual chimney inspection.
What to check before the pro arrives
Pellet stove pipe installation is a job for a certified pro, and the checks below are planning checks, not install steps. Work through them in order:
- Flue outlet diameter: read the stove’s flue outlet size and match the pipe diameter to it, 3-inch or 4-inch.
- Pipe lengths: count the lengths the run needs, using the 24-inch and 36-inch pipe lengths and the 22.5-inch installed length in the listings.
- Route: decide whether the run goes through the wall or up through the roof, and use a thru-the-wall kit for a horizontal run.
- Clearance: check the 1-inch clearance to combustibles along the whole route.
- Listing: confirm the listing on the pipe, such as UL 641 on the DuraVent 4-inch pipe and the Stove Parts 4 Less kit.
- Fresh air: check whether the stove needs an outside air intake, and look at the Coldairsoap kit if it does.
- Warranty: note the warranty terms: the DuraVent PelletVent Pro pipes state a limited lifetime warranty, and the Stove Parts 4 Less kit states a 90-day warranty on manufacturer defects.
For the tools and supplies that go with the stove, see pellet stove maintenance.
FAQ: wood, fire and gear
What size stove pipe does a pellet stove need?
Match the pipe to the stove’s flue outlet. The listings show 3-inch and 4-inch Type L pipe, and Selkirk sells thru-the-wall kits in 3-inch and 3-4-inch sizes. A 3-inch outlet takes 3-inch pipe, and a 4-inch outlet takes 4-inch pipe.
What is Type L pellet vent pipe?
It is double-wall vent pipe made for pellet stoves. The DuraVent 4-inch pipe describes a 444/304 stainless steel inner wall with a galvalume steel outer wall, twist-lock joints, and a UL 641 listing, rated for continuous flue temperatures up to 570°F.
How much clearance does pellet stove pipe need?
The DuraVent and Stove Parts 4 Less listings state 1-inch clearance to combustibles, in the USA and Canada. Keep that gap along the whole run, and check the listing on the pipe.
Can pellet stove pipe run horizontally?
The Selkirk thru-the-wall kits are designed for horizontal installations only, and DuraVent describes its pipe for horizontal and vertical runs. A horizontal run still needs the right diameter, clearance and listing, and a certified pro to install it.
What temperature can pellet stove pipe handle?
The DuraVent and Stove Parts 4 Less listings rate the pipe for continuous flue temperatures up to 570°F, and the Selkirk kits state that flue gases must not exceed 570°F. The Coldairsoap intake flex pipe is a different part, and its listing states up to 752°F.
Does a pellet stove need a fresh air intake?
It depends on the stove and the house, so check the stove’s manual. The Coldairsoap kit is a fresh air intake kit: a flex pipe that stretches to 59 inches, 3 wall plates, 1 flex pipe, 2 clamps and 3 hole saws, with a 45-degree weatherboard that keeps rain and leaves out.
More firewood guides
See the stove accessories guides, stove pipe sizes, the pellet stove installation kit, pellet stove maintenance and stove pipe vs chimney pipe.