Wood Burning Stove Installation Kit: Parts You Need
A wood burning stove installation kit connects the stove to the chimney: 6 inch stovepipe, a ceiling support box, roof flashing, a storm collar and cap, with wall heat shield spacers as a separate kit.

On this page
Top picks at a glance
As an Amazon Associate I earn from qualifying purchases.
- 1
3' X 8' Grill Heat Shield for Deck Railing9.3/10View on Amazon - 2
Aluminum Heat Shield Board9.4/10View on Amazon - 3
Firebox Folding Camp Cook Stove KitView on Amazon - 4
SONRETView on Amazon - 5
Criditpid PBAR-2427 Fireplace Blower Fan Kit for PleasantView on Amazon - 6
SARDVISA Wood Burning KitView on Amazon - 7
US Stove Door Glass KitView on Amazon - 8
Criditpid 40256 & 40257 Shaker Grate Frame Kit for US StoveView on Amazon
A wood stove arrives ready to burn, but the pipe that carries the smoke out usually comes separately. A wood burning stove installation kit is the set of parts that connects the stove to the chimney: stovepipe, a ceiling support, roof flashing, a storm collar and a cap, plus the wall protection that keeps heat off the house. This guide lays out what each part does and what to check before a certified pro puts it in.
More options to weigh up
Firebox Folding Camp Cook Stove KitCheck price on Amazon
SONRETCheck price on Amazon
Criditpid PBAR-2427 Fireplace Blower Fan Kit for PleasantCheck price on Amazon
SARDVISA Wood Burning KitCheck price on Amazon
US Stove Door Glass KitCheck price on Amazon
Criditpid 40256 & 40257 Shaker Grate Frame Kit for US StoveCheck price on Amazon
FirewoodGearHQ earns a small commission if you buy through links on this page. The price you pay stays the same. Read our affiliate disclosure.
Wood burning stove installation kit: the short answer
A kit is a matched set of parts, not a single pipe. The DuraPlus manufactured home kit shows the full through-the-roof pattern: a ceiling support where the flue passes the ceiling, flashing and a storm collar at the roof, a cap on top, and chimney pipe sections, with a DVL/DuraBlack adapter where it meets the stovepipe. The DuraVent DVL kit is the 6 inch stovepipe itself, and the wall heat shield spacers are a separate kit.
| Part | What it does | What the listings show |
|---|---|---|
| Stovepipe, double-wall | Connects the stove to the chimney | 6 inch diameter, DuraVent DVL close clearance kit |
| Ceiling support box | Carries the chimney through the ceiling | 24 inch square, with trim, in the DuraPlus manufactured home kit |
| Roof flashing | Seals the chimney where it passes the roof | Adjustable, 0/12 to 6/12 pitch, in the DuraPlus kit |
| Storm collar and cap | Keeps rain out and tops the chimney | Included in the DuraPlus manufactured home kit |
| Chimney pipe sections | Runs the flue above the roof | 2 sections of 24 inch galvanized DuraPlus pipe in the kit; the basic kit supports up to 35 feet of pipe, not included |
| Wall heat shield spacers | Holds a heat shield board off a combustible wall | 8 or 10 spacers with screws and anchors; board not included |
Match the diameter first
Every pipe listing cited here is 6 inch diameter: the DuraVent DVL connector kit, the DuraPlus manufactured home kit and the DuraPlus basic through-the-ceiling kit. Check the stove outlet size against that diameter before ordering, and match the pipe to the stove manual. For the sizes in more detail, see our stove pipe sizes guide and the chimney liner size chart.
The parts in the kit
Stovepipe
The stovepipe runs from the stove to the chimney. The DuraVent DVL listing is a 6 inch diameter double-wall close clearance connector kit, with listed product dimensions of 15.0 x 7.5 x 33.0 inches. Double-wall pipe is the connector piece between the stove and the chimney pipe.
Ceiling support and flashing
The DuraPlus manufactured home kit is the full through-the-roof set: a 24 inch square ceiling support box with trim, a DVL/DuraBlack adapter, adjustable roof flashing for 0/12 to 6/12 pitch, a storm collar, a chimney cap, and 2 sections of 24 inch galvanized DuraPlus chimney pipe. The pipe is triple-wall with a locked-in ceramic refractory blanket and an air space insulation layer. The listing states it meets UL standards for continuous 1,000°F flue gas, and states a limited lifetime warranty. The kit lists a weight of 43.0 pounds and is made for manufactured homes, for flat or cathedral ceilings.
The basic through-the-ceiling kit
The DuraPlus basic through-the-ceiling kit is the lighter set: it supports up to 35 feet of pipe, not included, in 24-gauge triple-wall construction. The listing gives a weight of 28.0 pounds. Pipe length comes from the roof height and the run above it, so count the sections before ordering.
Wall heat shield spacers
Wall protection is a separate kit. The Otoolling 8-set includes 8 metal wall spacers, 8 screws, 8 expansion anchors, 8 fish eye washers and 8 nails, a 40-piece set in all, and the board or panel is not included. The Otoolling 10-piece kit includes 1 inch 10 black spacers, 10 screws and 10 anchors, in heat and corrosion resistant metal. The spacers hold a heat shield board away from a combustible wall so air can move behind the board during stove use. Confirm the board size, wall construction and installation method before purchasing, per the listings.
What to check before the pro arrives
- Stove outlet size matches the 6 inch pipe in the listings
- Ceiling type: flat or cathedral, both listed for the DuraPlus manufactured home kit
- Roof pitch fits the flashing in the kit, adjustable from 0/12 to 6/12 pitch
- Pipe length: the basic kit supports up to 35 feet of pipe, not included
- Wall construction and board size for the heat shield spacers, since the board is not included
- Local code and the stove maker instructions, and a certified pro for the install
- Smoke and CO alarms in place, and an annual chimney inspection on the calendar
- Seasoned wood only, for a cleaner burn
Safety
Install per the maker and local code, keep clearances as the maker states, and have smoke and CO alarms in place with an annual chimney inspection. Burn seasoned wood only. This guide does not give installation steps: a certified pro should do the install. For safe burning practice, see the U.S. EPA’s Burn Wise program.
FAQ: wood, fire and gear
What is in a wood burning stove installation kit?
The kits cited here cover the parts that connect a stove to a chimney: the DVL connector kit is the 6 inch stovepipe, and the DuraPlus manufactured home kit holds a ceiling support box, roof flashing, a storm collar, a cap and chimney pipe sections. Wall heat shield spacers come as a separate kit, with screws and anchors, and the board is not included.
What size stovepipe do I need?
Match the pipe to the stove outlet and the stove manual. The listings cited here are all 6 inch diameter pipe, from the DuraVent DVL connector kit to the DuraPlus chimney kits. Check the diameter before ordering.
How much chimney pipe do I need?
It depends on the roof height and the run above it. The DuraPlus basic kit supports up to 35 feet of pipe, not included, while the DuraPlus manufactured home kit includes 2 sections of 24 inch pipe. Count the sections before ordering.
Do I need a heat shield for a wood stove?
A heat shield board protects a combustible wall near the stove, and spacers hold the board off the wall so air can move behind it. The Otoolling kits include 8 or 10 spacers with screws and anchors, and the board is not included. Confirm the board size, wall construction and installation method before purchasing.
Can I install a wood stove myself?
This guide does not give installation steps. Stove and chimney installs should follow the maker instructions and local code, and a certified pro should do the work. Check local requirements before the job starts.
More firewood guides
See the stove accessories hub, the best chimney pipe picks and the best storm collar for chimney picks. For the stove itself, see the wood stove sizes guide and the best wood stoves picks.